Industrial Plug & Socket Coupling |
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
4
|
Dimension(mm)
|
a |
140
|
152
|
b |
95
|
104
|
c |
56
|
65
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-114/HJ-124
Current(A):16A,32A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
5
|
Dimension(mm)
|
a |
139
|
153
|
b |
96
|
107
|
c |
63
|
70
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-115/HJ-125
Current(A):16A,32A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
4h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
168
|
190
|
b |
92
|
102
|
c |
50
|
65
|
φ
|
7-20
|
7-20
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-113L-4/HJ-123L-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125 |
3
|
Dimension(mm)
|
a |
168
|
190
|
b |
92
|
102
|
c |
50
|
65
|
φ
|
7-20
|
7-20
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-113L/HJ-123L
Current(A):16A,32A
Voltage(V):220-240V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125 |
4
|
Dimension(mm)
|
a |
170
|
190
|
b |
95
|
104
|
c |
50
|
64.5
|
φ
|
7-20
|
7-20
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-114L/HJ-124L
Current(A):16A,32A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
5
|
Dimension(mm)
|
a |
166
|
190
|
b |
100
|
107
|
c |
63
|
70.5
|
φ
|
7-20
|
7-20
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-115L/HJ-125L
Current(A):16A,32A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
4h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
105
|
113
|
b |
92
|
104
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-113F-4/HJ-123F-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
105
|
113
|
b |
92
|
104
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-113F/HJ-123F
Current(A):16A,32A
Voltage(V):220-240V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
4
|
Dimension(mm)
|
a |
107
|
113
|
b |
95
|
104
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-114F/HJ-124F
Current(A):16A,32A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
5
|
Dimension(mm)
|
a |
110
|
115
|
b |
96
|
107
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-115F/HJ-125F
Current(A):16A,32A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
4h
|
63
|
125 |
3
|
Dimension(mm)
|
a |
135
|
157
|
b |
82
|
106
|
c |
50
|
65
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-113C-4/HJ-123C-4
Current(A):16A,32A
Voltage(V):110-130V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
3
|
Dimension(mm)
|
a |
135
|
157
|
b |
82
|
106
|
c |
50
|
65
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-113C/HJ-123C
Current(A):16A,32A
Voltage(V):220-240V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
4
|
Dimension(mm)
|
a |
140
|
157
|
b |
97
|
106
|
c |
56
|
65
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-114C/HJ-124C
Current(A):16A,32A
Voltage(V):380-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
16
|
32 |
5
|
Dimension(mm)
|
a |
140
|
158
|
b |
104
|
110
|
c |
63
|
70
|
φ
|
3-18
|
3-18
|
Cable nominal
cross-section area(mm2)
|
1-2.5 |
2.5-6
|
|
|
HJ-115C/HJ-125C
Current(A):16A,32A
Voltage(V):220-380V~
240-415V~
Protection degree:IP44
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125 |
3
|
Dimension(mm)
|
a |
134
|
154
|
b |
311
|
338
|
c |
108
|
122
|
d
|
111
|
130
|
e |
20 |
20 |
f |
155 |
187 |
g |
6 |
6.2
|
Cable nominal
cross-section area(mm2)
|
6-25 |
25-70
|
|
|
HJ-133/HJ-143
Current(A):63A,125A
Voltage(V):220-240V~
Protection degree:IP67
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125 |
4
|
Dimension(mm)
|
a |
134
|
154
|
b |
311
|
338
|
c |
108
|
122
|
d
|
111
|
130
|
e |
20 |
20 |
f |
155 |
187 |
g |
6 |
6.2
|
Cable nominal
cross-section area(mm2)
|
6-25 |
25-70
|
|
|
HJ-134/HJ-144
Current(A):63A,125A
Voltage(V):380-415V~
Protection degree:IP67
|
|
|
|
|
Earth contact position
Rated current(A)
|
Pole
|
6h
|
63
|
125 |
5
|
Dimension(mm)
|
a |
134
|
154
|
b |
311
|
338
|
c |
108
|
122
|
d
|
111
|
130
|
e |
20 |
20 |
f |
155 |
187 |
g |
6 |
6.2
|
Cable nominal
cross-section area(mm2)
|
6-25 |
25-70
|
|
|
HJ-135/HJ-145
Current(A):63A,125A
Voltage(V):220-380V~
240-415V~
Protection degree:IP67
|
|
|
|
|
|