3UA Thermal relay
|
|
|
Application
|
|
3UA thermal relay is suitable for A.C. 50/60Hz .voltage up to 690-1000V and current up to 630A. general AC motor of long or discontinuous long operation, and trip inducation. It can automati cally and manually get back, phase protection, temperature compensation, and trip indication. It can automati cally and manually get back. It can be fixed with contactor together, also be independtiy fixed. The product comforms to GB14048.4, IEC60947-4 & VDE0660 stardands.
|
|
Type and
|
|
|
|
Motion Characteristic:Three-Phase Balance Motion Time
|
|
No.
|
Set current cinles |
Motion time
|
Start conidition
|
Temperature
|
4 |
1.05
|
>2h
|
cold state
|
20±5℃
|
3 |
1.2
|
<2h
|
heat state
Following the No.1 test)
|
2 |
1.5
|
<4min
|
1 |
7.2
|
10A
|
2s<Tp≤10s
|
≤63A
|
cold state
|
10A
|
2s<Tp≤10s
|
>63A
|
|
|
Phase-losing motion characteristic
|
|
No.
|
Set current cinles
|
Motion
time
|
Start
conidition
|
Temperature
|
Arbitrary two phase |
Three Phase
|
1 |
1.0 |
0.9
|
>2h
|
cold state |
20±5℃
|
2 |
1.15 |
0 |
<2h
|
heat state
(Following the
No.1 test)
|
|
|
Tripcharacteristic
|
|
Thermal relay manual reset time is ≤2min or blow auto reset time is ≤5min(Rated
current ≤63A) or ≤8min (Rated current >63A)
|
|
|
Specificarions
|
|
Type |
Number |
Setting Range(A) |
Contavtor Insert |
3UA-12/Z |
0A
|
0.1~0.16
|
CJX1-9
CJX1-12
|
0C
|
0.16~0.25
|
0E
|
0.25~0.4
|
0G
|
0.4~0.63
|
0J
|
0.63~1
|
0K
|
0.8~1.25
|
1A
|
1~1.6
|
1B
|
1.25~2
|
1C
|
1.6~2.5
|
1D
|
2~3.2
|
1E
|
2.5~4
|
1F
|
3.2~5
|
1G
|
4~6.3
|
1H
|
5~8
|
1J
|
6.3~10
|
1K
|
8~12.5
|
2S
|
10~14.5
|
|
|
Type |
Number |
Setting Range(A) |
Contavtor Insert |
3UA-25/Z
|
0A
|
0.1~0.16
|
CJX1-16
CJX1-22
|
0C
|
0.16~0.25
|
0E
|
0.25~0.4
|
0G
|
0.4~0.63
|
0J
|
0.63~1
|
0K
|
0.8~1.25
|
1A
|
1~1.6
|
1B
|
1.25~2
|
1C
|
1.6~2.5
|
1D
|
2~3.2
|
1E
|
2.5~4
|
1F
|
3.2~5
|
1G
|
4~6.3
|
1H
|
5~8
|
1J
|
6.3~10
|
1K
|
8~12.5
|
2A
|
10~16
|
2B
|
12.5~20
|
2C
|
16~25
|
|
|
Type |
Number |
Setting Range(A) |
Contavtor Insert |
3UA-32/Z |
1G
|
4~6.3
|
CJX1-32
|
1J
|
6.3~10
|
2A
|
10~16
|
2B
|
12.5~20
|
2C
|
16~25
|
2D
|
20~32
|
2Q
|
25~36
|
3UA-45/Z
|
0A
|
0.1~0.16
|
CJX1-32
CJX1-38F
CJX1-38
|
0V
|
0.16~0.25
|
0E
|
0.25~0.4
|
0G
|
0.4~0.63
|
0J
|
0.63~1
|
0K
|
0.8~1.25
|
1A
|
1~1.6
|
1B
|
1.25~2
|
1C
|
1.6~2.5
|
1D
|
2~3.2
|
1E
|
2.5~4
|
1F
|
3.2~5
|
1G
|
4~6.3
|
1H
|
5~8
|
1J
|
6.3~10
|
1K
|
8~12.5
|
2A
|
10~16
|
2B
|
12.5~20
|
2C
|
16~25
|
2D
|
20~32
|
2Q
|
25~36
|
2R
|
32~40
|
8M
|
36~45
|
3UA-80/Z
|
1G
|
4~6.3
|
CJX1-45
CJX1-63
|
8A
|
11~17
|
2B
|
12.5~20
|
2C
|
16~25
|
2D
|
20~32
|
2E
|
25~40
|
2F
|
32~50
|
2T
|
40~57
|
2P
|
50~63
|
2V
|
57~70
|
2U
|
63~80
|
8W
|
70~88
|
3UA-63/F
|
0A
|
0.1~0.16
|
CJX1-9
CJX1-63
|
0C
|
0.16~0.25
|
0E
|
0.25~0.4
|
0G
|
0.4~0.63
|
0J
|
0.63~1
|
|
|
Type
|
Number
|
Setting Range(A)
|
Contavtor Insert
3UA Thermal relay
|
3UA-63/F
|
0K
|
0.8~1.25
|
CJX1-9
CJX1-63
|
1A
|
1~1.6
|
1B
|
1.25~2
|
1C
|
1.6~2.5
|
1D
|
2~3.2
|
1E
|
2.5~4
|
1F
|
3.2~5
|
1G
|
4~6.3
|
1H
|
5~8
|
1J
|
6.3~10
|
1K
|
8~12.5
|
2A
|
10~16
|
2B
|
12.5~20
|
2C
|
16~25
|
2D
|
20~32
|
2E
|
25~40
|
2M
|
32~45
|
2T
|
40~57
|
2P
|
50~63
|
3UA-135
|
2H
|
55~80
|
|
2W
|
63~90
|
2X
|
80~110
|
3H
|
90~120
|
3J
|
110~135
|
3UA-150
|
2H
|
55~80
|
CJX1-140
|
2W
|
63~90
|
2X
|
80~110
|
3H
|
90~120
|
3J
|
110~135
|
3K
|
120~150
|
3UA-180/F
|
2H
|
55~80
|
CJX1-110
CJX1-170
|
2W
|
63~90
|
2X
|
80~110
|
3H
|
90~120
|
3J
|
110~135
|
3K
|
120~150
|
3L
|
135~160
|
3M
|
150~180
|
3UA-400
|
2K
|
80~125
|
CJX1-250
CJX1-400
|
3B
|
125~200
|
3C
|
160~250
|
3D
|
200~320
|
3E
|
250~400
|
3UA-630
|
3F
|
320~500
|
CJX1-400
CJX1-475
|
3G
|
400~630
|
|
|